Specifications
Characteristics
|
Unit
|
Value/Performance
|
Comments
|
|
|
SM
|
MM
|
|
SPC
|
UPC
|
Basic
|
Insertion Loss(IL)
|
dB
|
≤0.3
|
IEC 61300-3-4
|
Return Loss(RL)
|
dB
|
SPC≥45
|
≥50
|
≥23
|
IEC 61300-3-6
|
Endurance
|
dB
|
??IL≤0.2
|
IEC 61300-2-2,coupling and uncoupling 500 cycles,
clean every 25 cycles
|
Operating Temperature
|
??
|
-40~+70
|
|
Storage Temperature
|
??
|
-40~+70
|
|
Mechanical
|
Drop
|
dB
|
??IL≤0.2
|
IEC 61300-2-12,1.5m,5 drops,no damage
|
Vibration
|
dB
|
??IL≤0.2
|
IEC 61300-2-1,10-55Hz, 0-75mm amplitude,
0.5hrs/axis
|
Flex
|
dB
|
??IL≤0.2
|
Telcordia GR326(4.4.3.2),0.9kg,±90°,
100cycles,for 2mm or larger cable
|
Twist
|
dB
|
??IL≤0.2
|
Telcordia GR326(4.4.3.2),1.35kg, load±2.5 tums,
100cycles,for 2mm or larger cable
|
Pull Proof
|
dB
|
??IL≤0.2
|
Telcordia GR326(4.4.3.2),3.4kg at 90°,6.8kg at 0°,
for 2mm or larger cable
|
Environmental
|
Salt mist
|
|
No sign of corrosion
|
IEC 61300-2-26, 5% NaC1, 30°C, 7 days
|
Cold
|
dB
|
??IL≤0.2
|
IEC 61300-2-17, -20??,96hrs
|
Dry Heat
|
dB
|
??IL≤0.2
|
IEC 61300-2-18, 70??, 96hrs
|
Damp Heat
|
dB
|
??IL≤0.2
|
IEC 61300-2-19, 40??,95%RH, 96hrs
|
|